How an interceptor trap works
The trap is a U-shaped bend built into the floor of the chamber, usually in glazed clay. Like the trap under a sink, it holds water, which forms a seal between the house drains and the sewer beyond. Above the outgoing side is a short pipe called the rodding eye, which lets the sewer side be cleared without going through the trap.
The rodding eye is closed by a stopper, a clay or plastic plug held in place by its own fit, sometimes with a small chain. If the sewer side backs up, pressure can push the stopper out, which is part of its design.
Why does my interceptor trap keep blocking?
The bend creates a step that waste must climb. Wipes, sanitary items, kitchen grease and paper can lodge there, especially if flow from the house is weak. Over time scale and fat narrow the bend further, so each blockage comes back faster.
A loose stopper is another common cause. When it falls out, it drops into the trap itself and blocks it, and waste then bypasses the seal through the open rodding eye. A chamber that fills to the brim with the channel at the bottom invisible is often a stopper problem.
Signs the trap is the problem
Lift the last chamber cover before the boundary. If it is full and the chamber before it is also full, the blockage is likely at the trap or beyond. If you can see the U-shaped bend at the outlet end, with or without the stopper in place, you have an interceptor trap. Water standing at the level of the bend is normal; water rising above the benching is not.
Clearing it safely
Clearing an interceptor trap needs the right rods and a careful approach, because forcing debris through can push the stopper into the trap or crack old clay. The bend should be cleared from the chamber, and the rodding eye used for the sewer side. Afterwards it is worth checking the stopper fits and the clay around it is sound. Our blocked manhole page covers chamber clearances more generally.
Should an interceptor trap be removed?
Some people choose to replace a troublesome trap with a straight-through channel. That improves flow and removes the step where waste collects. The trade-off is that the barrier to sewer gas and rats is lost, so the decision depends on the drain's condition, the sewer side and local requirements. Where the drain connects to a public sewer, it is usually wise to check with the water company before altering the connection.
Other options include fitting a modern stopper that stays in place, or adding a non-return valve that keeps rats out while allowing better flow. A camera inspection either side of the trap helps decide which suits your drain.
Interceptor trap replacement
Replacement means breaking out the old trap from the chamber benching, fitting a new channel or trap, and reforming the benching around it. The chamber may also be repaired at the same time if its walls or benching have deteriorated.
Need it sorted? Book blocked manhole clearance
If the last chamber before the sewer keeps filling, book blocked manhole clearance and ask about the trap and stopper while George is there. Ring 0333 335 7414, message 07428 535083 on WhatsApp or use the quote form. Photos of the open chamber taken from above are helpful.
Want a professional to handle it?
Tell George about the problem using the enquiry form below.
Frequently asked questions
Why does my interceptor trap keep blocking?
Its U-bend creates a step where wipes, grease and paper collect, and a stopper that falls out drops straight into the trap. Repeated blockages usually mean one of those, or scale narrowing the bend.
Should an interceptor trap be removed?
It can be replaced with a straight channel to improve flow, but that removes the barrier against sewer gas and rats. Check the drain's condition and, where it joins a public sewer, the water company's view first.
What is the stopper in my manhole for?
It plugs the rodding eye above the trap, which is used to clear the sewer side. If it comes loose, it can block the trap below it.
Is an interceptor trap the same as a grease trap?
No. A household interceptor trap is a water seal in the last chamber. A grease trap or interceptor in a commercial kitchen separates fat from wastewater.